Heat pump air - water MONOBLOCK
The monoblock heat pump is a compact system for outdoor installation, which means that the space inside remains free. It is suitable for installation in all types of properties, especially locations where space is limited.
Through Air-to-Water heat pump technology, energy from the outside air is transformed into heat that is used to heat your home and produce DHW. The technology is also used for cooling. The main advantage is that up to 75% of the required energy is extracted from the outside air.
Many applications in one system
Heating, cooling and DHW with only one system.
Domestic Hot Water
Water temperature: 25-60 °C
Underfloor heating
Water temperature: 30-35 °C
Steam
Water temperature: 40-50 °C
Cooling / Heating
Water temperature: 30-45 °C
* When selecting two different temperatures, which requires control of 2 zones, the set water temperature in heating mode must be the higher one.
* If terminal units are connected for both heating and cooling, installation of a 2-way valve on the heating circuit is required, which is controlled by the heat pump and stops the water flow in cooling mode.
Freon R32 (HFC-32) with 0 ODP and 675 GWP, low carbon content and no harm to the ozone layer. R32 contributes to environmental protection by reducing CO2 emissions by 77%, compared to R410a.
Integrated hydraulic module
In the case of the monobloc heat pump, the indoor and outdoor units are combined in one module. There are no refrigerant connections as the monoblock is connected solely by water. At the same time, components such as the plate heat exchanger, expansion tank and water pump are pre-included in the package.
High efficiency compressor
Thanks to a high-efficiency compressor, a large-area heat exchanger and a precise control system, the heat pump maintains a high temperature even at low outside temperatures.
High performance components

DC inverter compressor
Pressure coefficient up to 13. Good efficiency at low temperatures

Brushless DC motor
with high efficiency and low noise levels.

Freon cooling of the board
Ensures the main board operates within appropriate temperature ranges to improve its reliability.

High efficiency plate heat exchanger.
Excellent airflow design, resistant to high temperatures and pressure.

TRB
Precisely controls and regulates refrigerant flow, 0-480 pulse.

Inverter water pump
High-efficiency inverter water pump operating at high pressure up to 9 m.
Multiple protections
The unit has a number of built-in protections to ensure the long-term stable and safe operation of the entire heat pump system.
Protection by current
- Protection against excessive amperage in the system
Protection by voltage
- High Voltage Protection
- Low voltage protection
Protection by pressure
- High pressure protection
- Low pressure protection
Protection against overheating
- Compressor outlet temperature
- Condenser temperature
- IPM module overheating protection
Protection against freezing
- Water temperature sensor
- Freon temperature sensor
High water temperature
The monobloc heat pump operates over a wide outdoor temperature range, from -25°C to 43°C. It provides hot water for heating/ DHW at temperatures up to 62°C throughout the year. It is extremely suitable for residential and commercial applications.
Silent night mode
Through a simple setting from the controller, a time can be set for the heat pump to enter quiet mode, where the noise level is reduced to 3 dB(A).
Energy labels and certificates
As a basic energy-efficient and reliable heat pump, the monoblock has received a series of certifications to meet the needs of different markets.
Management
The air-to-water monobloc heat pumps have 3 different ways of controlling the unit to meet specific customer requirements.
Protection against overheating
- Compressor outlet temperature
- Condenser temperature
- IPM module overheating protection
Wi-Fi wired control with touch screen
- Management Mode
- Weekly timer function
- Electric heater
- Forced unloading
- Sterilization
- Protection against freezing
- Wi-Fi control
Dry contact
The heat pump retains 3 standard dry contacts and 4 customized dry contacts, as well as 3 standard 230 V outlets and 3 customized 230 V outlets.
Modbus control
The board of the outdoor unit has a built-in Modbus control port, which allows it to be connected to an external control or a PC via Modbus protocol.
Dimensions of the appliance
| Model | Number of phases | Fan | A (mm) | B (mm) | C (mm) | D (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|
| 16 kW | 1 Ph | Double | 1302 | 1517 | 370 | 465 | 165.5 |
Technical characteristics
| Technical parameters in heating mode | |||
| A+7°C; W30/35°C | Power/COP | kW/COP | 16.00/4.60 |
| A+2°C; W30/35°C | Power/COP | kW/COP | 14.50/3.30 |
| A-7°C; W30/35°C | Power/COP | kW/COP | 13.30/2.70 |
| A+7°C; W40/45°C | Power/COP | kW/COP | 16.00/3.50 |
| A+7°C; W47/55°C | Power/COP | kW/COP | 13.50/2.70 |
| A+2°C; W47/55°C | Power/COP | kW/COP | 13.50/2.35 |
| A-7°C; W47/55°C | Power/COP | kW/COP | 11.50/1.95 |
| A+7°C; W35°C (ErP-moderate climate) |
Prated-NET/SCOP-NET | 14.79/4.78 | |
| ηs 30/35-NET | % | 188% | |
| Efficiency class 30/35 | A+++ | ||
| A+7°C; W55°C (ErP-moderate climate) |
Prated-NET/SCOP-NET | 13.06/3.36 | |
| ηs 47/55-NET | % | 131% | |
| Energy class 47/55 | A++ | ||
| Technical parameters in cooling mode | |||
| A+35°C; W23/18°C | Power | kW | 14.30 |
| EER/SEER | 3.80/6.14 | ||
| ηs 23/18 | % | 243% | |
| A+35°C; W12/7°C | Power | kW | 14.00 |
| EER/SEER | 2.65/5.06 | ||
| ηs 23/18 | % | 199% | |
| Technical characteristics | |||
| Sound characteristics | Sound power | dB(A) | 70 |
| Sound pressure | dB(A) | 58 | |
| Dimensions | LxWxH | mm | 1302x465x1517 |
| Weight | Weight | kg | 167.7 |
| Freon | Type/quantity | kg | R32/2.6 |
| Water connections | Diameter of inlet pipes | inch | 1.25 |
| Ex. pipe diameter | inch | 1.25 | |
Personal consultation
Contact us for a free personal consultation. Our team will help you choose the best solution for your needs.